    Technical Details

     

    Micro-flow Intelligent Integrated Black Odorous Water Treatment System

    Technology | Shengjian Environmental Technology (Wuhan) Co., Ltd.

    Black odorous water treatment generally follows the route of "external source reduction, internal source dredging, water quality purification, clean water replenishment and ecological restoration". In engineering practice, conventional internal and external source control and in-situ purification technologies are easily affected by environmental conditions, resulting in large fluctuations in water quality and high costs; in townships and small watersheds, integrated ex-situ systems are widely adopted due to their short construction period and flexible use. At the same time, discharge standards continue to tighten, and many indicators are now required to meet Class IV surface water standards.

    Guided by the goals of "reducing energy consumption, saving land, improving efficiency and enabling intelligent operation", the micro-phase-flow intelligent integrated system restructures the core processes of the physico-chemical and biological stages, and consists of three units:

    Unit Positioning Main function
    Micropore Emission SystemPhysico-chemical pretreatment stageRemoves algae, suspended solids, total phosphorus and oils and greases, reducing the load on the biological stage
    Micro-oxygen Transfer Biological SystemMain biological unitRemoves dissolved organic matter (BOD), total nitrogen and other eutrophic substances
    Intelligent Control SystemThroughout the whole processMonitoring, scheme matching, visualization and remote management

    I. Micropore Emission System

    The main body consists of a drive motor, a speed regulating device, a silicon carbide emission head and an air intake device. Low-pressure air at 1 to 2 bar is introduced into the silicon carbide microporous emission head, which rotates at high speed to generate microbubbles of 50 to 70 μm. Pollutants adhere to the bubbles by surface tension and are enriched and skimmed off in the upper layer of the treatment unit. Together with chemical dosing, algae, suspended solids, total phosphorus and oils and greases can be removed.

    Compared with conventional dissolved air flotation, the differences lie in three aspects: pressure, air dissolution mode and recirculation:

    Comparison item Conventional physico-chemical flotation Micropore Emission System
    Air pressure5 to 7 bar1 to 2 bar
    Bubble generationRequires a dissolution tank with 3 to 5 minutes of retentionGenerated directly, no air dissolution required
    Recirculation rate5% to 30%No recirculation required
    Energy consumption0.2 to 0.5 kWh/m³0.05 kWh/m³
    FootprintLargeSmall
    Clogging riskRelease heads prone to cloggingNo release head; self-cleaning

    II. Micro-oxygen Transfer Biological System

    With conventional blower aeration, bubbles rise rapidly into the air and very little dissolved oxygen is actually available to microorganisms; more than 70% of the energy is wasted. In addition, nitrogen removal requires separate anoxic (A) and aerobic (O) tanks as well as sludge and nitrified liquor recirculation, resulting in a large footprint and complicated control.

    The approach here bypasses bubbles altogether. The core component is a submerged hollow-fiber gas-permeable membrane coated with a silica gel layer, made into standard modules that can either be prefabricated into the integrated system or used to upgrade and retrofit existing systems. Oxygen passes directly through the membrane wall to supply the biofilm growing on the membrane, without forming bubbles. BOD and ammonia diffuse from the liquid phase toward the membrane surface, while oxygen counter-diffuses from the membrane lumen outward, forming a stratified biofilm structure within a single reactor: close to the membrane surface is an aerobic autotrophic zone where ammonia nitrogen is oxidized to nitrate; in the middle is an aerobic heterotrophic zone where BOD is degraded; the outer layer tends to be anoxic, providing conditions for denitrification. Nitrification and denitrification therefore occur simultaneously in the same reactor, eliminating the need for separate stages and recirculation.

    This unit operates at a working pressure of only 100 to 200 mbar, with an oxygen transfer efficiency of up to 95% and an oxygen transfer rate 3 to 4 times that of conventional biological aeration; it is equipped with a biofilm thickness measurement technology that automatically sloughs off excess biofilm when the thickness exceeds process requirements; the amount of excess sludge can be reduced by more than 50%.

    III. Intelligent Control System

    The monitoring layer continuously or periodically collects key indicators such as flow, turbidity, TOC, total phosphorus and chlorophyll, while also monitoring equipment operating status. Taking the micropore emission system as an example, the rotational speed of the emission head is correlated with bubble size and gas output; the speed is dynamically adjusted according to the pollutant concentration in the influent rather than running at a constant rate.

    The analysis layer incorporates both raw water data and compliance requirements, matching treatment modes with historical data: when the water quality is simple, an automatic scheme is executed; when the water quality is unusual, human expertise intervenes. The visualization layer presents the water quality before and after treatment, real-time operating data, chemical consumption, membrane fouling degree and remaining membrane life via a mobile APP, and supports alarm prompts and one-click flushing and reset. The dynamic visualization of the treatment process is equivalent to a digital twin of this system.

    IV. Applicable Scenarios

    It is intended for polluted surface water bodies such as lakes, rivers and landscape waters, especially where self-purification capacity is difficult to restore, eutrophication is prominent and water quality needs to be improved within a relatively short time; it is also suitable for scenarios where a permanent station cannot be built or where treatment must be carried out alternately at multiple points. The number of modules can be increased or decreased according to the treatment scale and footprint requirements. It is a mobile ex-situ treatment solution, representing a different technological route from the fixed-station model of large municipal wastewater treatment plants.

    This article is for technical exchange only. The parameters stated are design and measured values from the R&D and pilot-test stages; actual engineering performance must be verified in light of the specific water quality, water temperature and operating conditions.






    Shengjian Environmental Technology (Wuhan) Co., Ltd.
    Address: Room 202, Bldg 15, Jinyinhu Science Park, Dongxihu District, Wuhan